# Sigenergy Sigen PV Max

Zdroj: https://docs.evcc.io/cs/meters/sigenergy-sigen-pv-max

Modbus TCP must be enabled in the configuration app with installer rights. This option is not available in the mySigen app for customers.

Podporované funkce: battery-control

## Parametry

| Název | Popis | Výchozí / příklad | |
| --- | --- | --- | --- |
| modbus | Modbus Type (tcpip) |  |  |
| capacity | Battery capacity | 50 kWh |  |
| minsoc | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | 0 % |  |
| maxsoc | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | 100 % |  |
| maxacpower | Maximum AC power of the hybrid inverter | 0 W | pokročilé |
| gateway | Sigen Energy Gateway installed Uses the "Backup SoC" register (40046) instead of "Discharge Cut-Off SoC" (40048) to block discharge. This keeps the house powered during a grid outage. | false | pokročilé |
| maxchargepower | Maximum charge power For forced charging of the battery. |  W | pokročilé |
| maxdischargepower | Maximum discharge power Maximum discharge power of the storage. |  W | pokročilé |

## Příklad konfigurace pro evcc.yaml

```yaml
meters:
    - name: my_grid
      type: template
      template: sigenergy
      usage: grid
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
```

```yaml
meters:
    - name: my_pv
      type: template
      template: sigenergy
      usage: pv
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
```

```yaml
meters:
    - name: my_battery
      type: template
      template: sigenergy
      usage: battery
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      capacity: 50 # Battery capacity (kWh), optional
      minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
      maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
      gateway: false # Sigen Energy Gateway installed, Uses the "Backup SoC" register (40046) instead of "Discharge Cut-Off SoC" (40048) to block discharge. This keeps the house powered during a grid outage. (optional)
      maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
      maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
```