# KACO blueplanet hybrid NH3

Kilde: https://docs.evcc.io/da/meters/kaco-blueplanet-hybrid-nh3

For KACO blueplanet Hybrid NH3 with AI dongle/Wi-Fi stick. Modbus TCP and the local AISWEI HTTP API must be reachable at the stick's IP address (Modbus TCP port 502, device ID 3; HTTP port 8484).
Battery power control uses the local `fdbg.cgi` endpoint. Maximum charge and discharge power are read from SunSpec Model 802. Battery charge and discharge energy are read from the local AISWEI HTTP API.
Configure curtailment through a separate KACO NH3 curtailer device.
The grid meter exposed through SunSpec Model 203 provides grid power, import/export energy, and per-phase measurements.

Understøttede funktioner: battery-control

## Parametre

| Navn | Beskrivelse | Standard / eksempel | |
| --- | --- | --- | --- |
| modbus | Modbus Type (tcpip) |  |  |
| battery | Battery number (1, 2) |  |  |
| serial | Inverter serial number (isn) |  |  |
| capacity | Battery capacity | 50 kWh |  |
| minsoc | Minimum charge Written to the inverter as the discharge limit and used by the optimizer. Only set a value supported by the battery. Minimum value is 5%. | 10 % |  |
| maxsoc | Maximum charge Written to the inverter as the charge limit and used by the optimizer. Only set a value supported by the battery. | 100 % |  |

## Konfigurationseksempel til evcc.yaml

```yaml
meters:
    - name: my_grid
      type: template
      template: kaco-nh3
      usage: grid
      
      # Modbus TCP
      modbus: tcpip
      id: 3
      host:  # Hostname
      port: 502 # Port
```

```yaml
meters:
    - name: my_pv
      type: template
      template: kaco-nh3
      usage: pv
      
      # Modbus TCP
      modbus: tcpip
      id: 3
      host:  # Hostname
      port: 502 # Port
```

```yaml
meters:
    - name: my_battery
      type: template
      template: kaco-nh3
      usage: battery
      
      # Modbus TCP
      modbus: tcpip
      id: 3
      host:  # Hostname
      port: 502 # Port
      battery: # Battery number, [1, 2]
      serial: # Inverter serial number (isn)
      capacity: 50 # Battery capacity (kWh), optional
      minsoc: 10 # Minimum charge (%), Written to the inverter as the discharge limit and used by the optimizer. Only set a value supported by the battery. Minimum value is 5%. (optional)
      maxsoc: 100 # Maximum charge (%), Written to the inverter as the charge limit and used by the optimizer. Only set a value supported by the battery. (optional)
```