# cFos Power Brain

Source: https://docs.evcc.io/en/chargers/cfos-power-brain

S0 meters must be configured separately as charge meter.
Phase switching is only available with the Solar variant and must be enabled by the user:
1) Home -> disable Load Balancing (Monitoring Mode)
2) Configuration -> Hardware - Phase switch / Relais 2 (enable phase switching)

Supported features: mA, rfid, 1p3p, dim

Sponsor token required: this device is available to sponsors of the project, see https://docs.evcc.io/en/sponsorship.

## Parameters

| Name | Description | Default / example | |
| --- | --- | --- | --- |
| host | IP address or hostname | 192.0.2.2 |  |

## Configuration example for evcc.yaml

```yaml
chargers:
    - name: my_charger
      type: template
      template: cfos
      host: 192.0.2.2 # IP address or hostname
```