# Mennekes AMTRON Professional

Source: https://docs.evcc.io/en/chargers/mennekes-amtron-professional

The 'Modbus TCP Server' must be enabled. The setting 'Register Address Set' must NOT be set to 'Phoenix' or 'TQ-DM100'. Use the third selection labeled 'Ebee', 'Bender', 'MENNEKES' etc. Set 'Allow UID Disclose' to On.

Firmware 5.33 or higher is required for phase switching (if supported by the model). The 'SEMP interface' must be enabled, the 'SEMP Charging Mode' must be set to 'Surplus Charging'. Set 'Software function to use phase switching' to SEMP.

For charging stations with two charging points (e.g. AMEDIO, Twincharge), each charging point must be configured separately. Set charging point 1 to Port 502 and charging point 2 to Port 503.

Supported features: meter, rfid, dim

Sponsor token required: this device is available to sponsors of the project, see https://docs.evcc.io/en/sponsorship.

## Parameters

| Name | Description | Default / example | |
| --- | --- | --- | --- |
| modbus | Modbus Type (tcpip) |  |  |

## Configuration example for evcc.yaml

```yaml
chargers:
    - name: my_charger
      type: template
      template: bender-cc
      
      # Modbus TCP
      modbus: tcpip
      id: 255
      host:  # Hostname
      port: 502 # Port
```