# TinkerForge WARP2 Smart + Energy Manager

Source: https://docs.evcc.io/en/chargers/tinkerforge-warp2-smart-plus-energy-manager

Firmware v2 required. WARP's own automatic phase switching will be deactivated by EVCC when connecting to the wallbox. See [docs.warp-charger.com](https://docs.warp-charger.com/docs/mqtt_http/api_reference/evse#evse_phase_auto_switch_warp3).

Supported features: mA, rfid, 1p3p, dim

## Parameters

| Name | Description | Default / example | |
| --- | --- | --- | --- |
| uri | URI HTTP(S) address |  |  |
| user | Username e.g. email address, user id, etc. |  |  |
| password | Password Service account password |  |  |
| energyManagerUri | Energy Manager URI HTTP(S) address of the WARP Energy Manager |  |  |
| energyManagerUser | Energy Manager Username e.g. email address, user id, etc. |  |  |
| energyManagerPassword | Energy Manager Password |  |  |
| energyMeterIndex | Energy Meter Index Index of the meter configured in the WARP charger whose values should be used. | 0 | advanced |

## Configuration example for evcc.yaml

```yaml
chargers:
    - name: my_charger
      type: template
      template: tinkerforge-warp2-em-ws
      uri: # URI, HTTP(S) address
      user: # Username, e.g. email address, user id, etc. (optional)
      password: # Password, Service account password (optional)
      energyManagerUri: # Energy Manager URI, HTTP(S) address of the WARP Energy Manager (optional)
      energyManagerUser: # Energy Manager Username, e.g. email address, user id, etc. (optional)
      energyManagerPassword: # Energy Manager Password, optional
      energyMeterIndex: 0 # Energy Meter Index, Index of the meter configured in the WARP charger whose values should be used. (optional)
```