Enter the host of the charger (not the GX device) and ensure that the charger is in manual mode.

To enable 1P/3P phase switching a hardware modification is required: the 4P contactor must be replaced with 2×2P contactors. The first contactor switches L1+N, the second switches L2+L3 and is controlled by the second relay on the PCB. Register 5100 must be set to 1 to enable phase switching.
[More info](https://community.victronenergy.com/t/charging-an-ev-with-excess-solar-switching-between-1p-and-3p/21181)

Supported features: 1p3p, meter, dim

## Parameters

| Name | Description | Default / example | |
| --- | --- | --- | --- |
| modbus | Modbus Type (tcpip) |  |  |

## Configuration example for evcc.yaml

```yaml
chargers:
    - name: my_charger
      type: template
      template: victron-evcs
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname