# Anker SOLIX X1 Hybrid Inverter

Source: https://docs.evcc.io/en/meters/anker-solix-x1-hybrid-inverter

The Modbus TCP interface must be enabled in the Anker app.
This configuration was tested with the Firmware Version 1.0.16.1.
Older or newer Firmware Versions may use different register addresses and therefore deliver incorrect data.

## Parameters

| Name | Description | Default / example | |
| --- | --- | --- | --- |
| modbus | Modbus Type (tcpip) |  |  |
| capacity | Battery capacity | 50 kWh |  |
| minsoc | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | 0 % |  |
| maxsoc | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | 100 % |  |
| maxacpower | Maximum AC power of the hybrid inverter | 0 W | advanced |
| maxchargepower | Maximum charge power For forced charging of the battery. |  W | advanced |
| maxdischargepower | Maximum discharge power Maximum discharge power of the storage. |  W | advanced |

## Configuration example for evcc.yaml

```yaml
meters:
    - name: my_grid
      type: template
      template: anker-solix-x1
      usage: grid
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
```

```yaml
meters:
    - name: my_pv
      type: template
      template: anker-solix-x1
      usage: pv
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
```

```yaml
meters:
    - name: my_battery
      type: template
      template: anker-solix-x1
      usage: battery
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      capacity: 50 # Battery capacity (kWh), optional
      minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
      maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
      maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
      maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
```