# Fronius Verto Plus

Source: https://docs.evcc.io/en/meters/fronius-verto-plus

Supported features: battery-control

## Parameters

| Name | Description | Default / example | |
| --- | --- | --- | --- |
| host | IP address or hostname | 192.0.2.2 |  |
| port | Port | 502 |  |
| capacity | Battery capacity | 50 kWh |  |
| minsoc | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | 0 % |  |
| maxsoc | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | 100 % |  |
| id | ID Meter address of primary or secondary meters. On the web interface of the inverter, only the address of the first meter (e.g., 200) can be set. Additional meters receive an ascending number (e.g., 201). | 200 | advanced |
| maxchargerate | Maximum charge rate For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. | 100 % | advanced |
| maxchargepower | Maximum charge power For forced charging of the battery. |  W | advanced |
| maxdischargepower | Maximum discharge power Maximum discharge power of the storage. |  W | advanced |

## Configuration example for evcc.yaml

```yaml
meters:
    - name: my_grid
      type: template
      template: fronius-vertoplus
      usage: grid
      host: 192.0.2.2 # IP address or hostname
      port: 502 # Port, optional
      id: 200 # ID, Meter address of primary or secondary meters. On the web interface of the inverter, only the address of the first meter (e.g., 200) can be set. Additional meters receive an ascending number (e.g., 201). (optional)
```

```yaml
meters:
    - name: my_pv
      type: template
      template: fronius-vertoplus
      usage: pv
      host: 192.0.2.2 # IP address or hostname
      port: 502 # Port, optional
```

```yaml
meters:
    - name: my_battery
      type: template
      template: fronius-vertoplus
      usage: battery
      host: 192.0.2.2 # IP address or hostname
      port: 502 # Port, optional
      capacity: 50 # Battery capacity (kWh), optional
      minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
      maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
      maxchargerate: 100 # Maximum charge rate (%), For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. (optional)
      maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
      maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
```