# GoodWe ET/EH/BT/BH Hybrid Inverter (WiFi)

Source: https://docs.evcc.io/en/meters/goodwe-et-eh-bt-bh-hybrid-inverter-wifi

Supported features: battery-control

## Parameters

| Name | Description | Default / example | |
| --- | --- | --- | --- |
| host | IP address or hostname | 192.0.2.2 |  |
| capacity | Battery capacity | 50 kWh |  |
| minsoc | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | 10 % |  |
| maxsoc | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | 100 % |  |
| delay | Delay | 0.1s | advanced |
| maxchargepower | Maximum charge power For forced charging of the battery. | 10000 W | advanced |
| maxdischargepower | Maximum discharge power Maximum discharge power of the storage. | 10000 W | advanced |

## Configuration example for evcc.yaml

```yaml
meters:
    - name: my_grid
      type: template
      template: goodwe-wifi-et
      usage: grid
      host: 192.0.2.2 # IP address or hostname
      delay: 0.1s # Delay, optional
```

```yaml
meters:
    - name: my_pv
      type: template
      template: goodwe-wifi-et
      usage: pv
      host: 192.0.2.2 # IP address or hostname
      delay: 0.1s # Delay, optional
```

```yaml
meters:
    - name: my_battery
      type: template
      template: goodwe-wifi-et
      usage: battery
      host: 192.0.2.2 # IP address or hostname
      capacity: 50 # Battery capacity (kWh), optional
      minsoc: 10 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
      maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
      delay: 0.1s # Delay, optional
      maxchargepower: 10000 # Maximum charge power (W), For forced charging of the battery. (optional)
      maxdischargepower: 10000 # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
```