## Parameters

| Name | Description | Default / example | |
| --- | --- | --- | --- |
| modbus | Modbus Type (rs485, tcpip) |  |  |
| capacity | Battery capacity Venus A 2.12 kWh, Venus D 2.56 kWh per base unit and per extension | 50 kWh |  |
| maxchargepower | Maximum charge power For forced charging of the battery. Venus A 1200 W, Venus D 2200 W |  W |  |
| maxdischargepower | Maximum discharge power Maximum discharge power of the storage. |  W |  |
| minsoc | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | 11 % |  |
| maxsoc | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | 100 % |  |
| work_mode_normal | Work mode for Normal state 0=manual, 1=anti-feed, 2=trade mode. | 1 | advanced |

## Configuration example for evcc.yaml

```yaml
meters:
    - name: my_pv
      type: template
      template: marstek-venus-a
      usage: pv
      
      # RS485 via adapter (Modbus RTU)
      modbus: rs485serial
      id: 1
      device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
      baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
      comset: "8N1" # Kommunikationsparameter für den Adapter
      
      # RS485 via TCP/IP (Modbus RTU)
      modbus: rs485tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      work_mode_normal: 1 # Work mode for Normal state, 0=manual, 1=anti-feed, 2=trade mode. (optional)
```

```yaml
meters:
    - name: my_battery
      type: template
      template: marstek-venus-a
      usage: battery
      
      # RS485 via adapter (Modbus RTU)
      modbus: rs485serial
      id: 1
      device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
      baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
      comset: "8N1" # Kommunikationsparameter für den Adapter
      
      # RS485 via TCP/IP (Modbus RTU)
      modbus: rs485tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      capacity: 50 # Battery capacity (kWh), Venus A 2.12 kWh, Venus D 2.56 kWh per base unit and per extension
      maxchargepower: # Maximum charge power (W), For forced charging of the battery. Venus A 1200 W, Venus D 2200 W
      maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage.
      minsoc: 11 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
      maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
      work_mode_normal: 1 # Work mode for Normal state, 0=manual, 1=anti-feed, 2=trade mode. (optional)
```