# Siemens Junelight Smart Battery

Source: https://docs.evcc.io/en/meters/siemens-junelight-smart-battery

The battery has to be set to Loxone with the installer account.

## Parameters

| Name | Description | Default / example | |
| --- | --- | --- | --- |
| modbus | Modbus Type (tcpip) |  |  |
| capacity | Battery capacity | 50 kWh |  |
| minsoc | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | 0 % |  |
| maxsoc | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | 100 % |  |
| maxchargepower | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. |  W | advanced |
| maxdischargepower | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. |  W | advanced |

## Configuration example for evcc.yaml

```yaml
meters:
    - name: my_grid
      type: template
      template: siemens-junelight
      usage: grid
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      timeout: 5s # optional
```

```yaml
meters:
    - name: my_pv
      type: template
      template: siemens-junelight
      usage: pv
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      timeout: 5s # optional
```

```yaml
meters:
    - name: my_battery
      type: template
      template: siemens-junelight
      usage: battery
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      timeout: 5s # optional
      capacity: 50 # Battery capacity (kWh), optional
      minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
      maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
      maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
      maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
```