# Sungrow iHomeManager (iHM)

Source: https://docs.evcc.io/en/meters/sungrow-ihomemanager-ihm

Supported features: curtail

## Parameters

| Name | Description | Default / example | |
| --- | --- | --- | --- |
| modbus | Modbus Type (tcpip, rs485) |  |  |
| capacity | Battery capacity | 50 kWh |  |
| minsoc | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | 0 % |  |
| maxsoc | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | 100 % |  |
| maxacpower | Maximum AC power of the hybrid inverter | 0 W | advanced |
| maxchargepower | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. |  W | advanced |
| maxdischargepower | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. |  W | advanced |

## Configuration example for evcc.yaml

```yaml
meters:
    - name: my_grid
      type: template
      template: sungrow-ihm
      usage: grid
      
      # RS485 via adapter (Modbus RTU)
      modbus: rs485serial
      id: 247
      device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
      baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
      comset: "8N1" # Kommunikationsparameter für den Adapter
      
      # RS485 via TCP/IP (Modbus RTU)
      modbus: rs485tcpip
      id: 247
      host:  # Hostname
      port: 502 # Port
      
      # Modbus TCP
      modbus: tcpip
      id: 247
      host:  # Hostname
      port: 502 # Port
```

```yaml
meters:
    - name: my_pv
      type: template
      template: sungrow-ihm
      usage: pv
      
      # RS485 via adapter (Modbus RTU)
      modbus: rs485serial
      id: 247
      device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
      baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
      comset: "8N1" # Kommunikationsparameter für den Adapter
      
      # RS485 via TCP/IP (Modbus RTU)
      modbus: rs485tcpip
      id: 247
      host:  # Hostname
      port: 502 # Port
      
      # Modbus TCP
      modbus: tcpip
      id: 247
      host:  # Hostname
      port: 502 # Port
      maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
```

```yaml
meters:
    - name: my_battery
      type: template
      template: sungrow-ihm
      usage: battery
      
      # RS485 via adapter (Modbus RTU)
      modbus: rs485serial
      id: 247
      device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
      baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
      comset: "8N1" # Kommunikationsparameter für den Adapter
      
      # RS485 via TCP/IP (Modbus RTU)
      modbus: rs485tcpip
      id: 247
      host:  # Hostname
      port: 502 # Port
      
      # Modbus TCP
      modbus: tcpip
      id: 247
      host:  # Hostname
      port: 502 # Port
      capacity: 50 # Battery capacity (kWh), optional
      minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
      maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
      maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
      maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
```