## Parameters

| Name | Description | Default / example | |
| --- | --- | --- | --- |
| modbus | Modbus Type (rs485, tcpip) |  |  |
| minsoc | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | 10 % |  |
| maxsoc | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | 100 % |  |
| maxchargepower | Maximum charge power For forced charging of the battery. | 1200 W |  |
| capacity | Battery capacity | 2.11 kWh |  |
| maxacpower | Maximum AC power of the hybrid inverter | 800 W | advanced |
| maxdischargepower | Maximum discharge power Maximum discharge power of the storage. |  W | advanced |

## Configuration example for evcc.yaml

```yaml
meters:
    - name: my_grid
      type: template
      template: fox-ess-avocado
      usage: grid
      
      # RS485 via adapter (Modbus RTU)
      modbus: rs485serial
      id: 1
      device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
      baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
      comset: "8N1" # Kommunikationsparameter für den Adapter
      
      # RS485 via TCP/IP (Modbus RTU)
      modbus: rs485tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
```

```yaml
meters:
    - name: my_pv
      type: template
      template: fox-ess-avocado
      usage: pv
      
      # RS485 via adapter (Modbus RTU)
      modbus: rs485serial
      id: 1
      device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
      baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
      comset: "8N1" # Kommunikationsparameter für den Adapter
      
      # RS485 via TCP/IP (Modbus RTU)
      modbus: rs485tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      maxacpower: 800 # Maximum AC power of the hybrid inverter (W), optional
```

```yaml
meters:
    - name: my_battery
      type: template
      template: fox-ess-avocado
      usage: battery
      
      # RS485 via adapter (Modbus RTU)
      modbus: rs485serial
      id: 1
      device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
      baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
      comset: "8N1" # Kommunikationsparameter für den Adapter
      
      # RS485 via TCP/IP (Modbus RTU)
      modbus: rs485tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      minsoc: 10 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer.
      maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging.
      maxchargepower: 1200 # Maximum charge power (W), For forced charging of the battery.
      capacity: 2.11 # Battery capacity (kWh), optional
      maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
```