# cFos Power Brain

Source: https://docs.evcc.io/fr/chargers/cfos-power-brain

S0 meters must be configured separately as charge meter.
Phase switching is only available with the Solar variant and must be enabled by the user:
1) Home -> disable Load Balancing (Monitoring Mode)
2) Configuration -> Hardware - Phase switch / Relais 2 (enable phase switching)

Fonctionnalités prises en charge: mA, rfid, 1p3p, dim

Jeton de parrain requis : cet appareil est disponible pour les parrains du projet, voir https://docs.evcc.io/fr/sponsorship.

## Paramètres

| Nom | Description | Par défaut / exemple | |
| --- | --- | --- | --- |
| host | IP address or hostname | 192.0.2.2 |  |

## Exemple de configuration pour evcc.yaml

```yaml
chargers:
    - name: my_charger
      type: template
      template: cfos
      host: 192.0.2.2 # IP address or hostname
```