The wallbox must be configured as satellite/slave using the DIP switches on the mainboard and Modbus RTU must be enabled (bank S1: 4=ON, 5=ON, 7=OFF).
No external meter should be connected directly to the wallbox, as all functions are controlled directly by evcc.
For Kostal systems with Smart Energy Meter (KSEM), the additional activation code (Solar Pure Mode / Solar Plus Mode) for the KSEM is *not* required.

Fonctionnalités prises en charge: rfid, mA, 1p3p, meter, dim

Jeton de parrain requis : cet appareil est disponible pour les parrains du projet, voir https://docs.evcc.io/fr/sponsorship.

## Paramètres

| Nom | Description | Par défaut / exemple | |
| --- | --- | --- | --- |
| modbus | Modbus Type (rs485) |  |  |

## Exemple de configuration pour evcc.yaml

```yaml
chargers:
    - name: my_charger
      type: template
      template: mennekes-compact
      
      # RS485 via adapter (Modbus RTU)
      modbus: rs485serial
      id: 50
      device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
      baudrate: 57600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
      comset: "8N2" # Kommunikationsparameter für den Adapter
      
      # RS485 via TCP/IP (Modbus RTU)
      modbus: rs485tcpip
      id: 50
      host:  # Hostname
      port: 502 # Port
```