# Askoma ASKOHEAT+

Source: https://docs.evcc.io/fr/heating/askoma-askoheatplus

The ASKOHEAT+ must be reachable via Modbus TCP (port 502).
Ensure "Load Setpoint" is enabled in Input Settings via the web interface.

**Important:** In the loadpoint configuration, set `mincurrent` and `maxcurrent` to match
your device, and configure `phases: 1` for single-phase operation.
Example AHIR-BI-plus-1.75: `mincurrent: 1.1`, `maxcurrent: 7.6` (at 230V, 1 phase).

Fonctionnalités prises en charge: meter, dim

## Paramètres

| Nom | Description | Par défaut / exemple | |
| --- | --- | --- | --- |
| modbus | Modbus Type (tcpip) |  |  |
| tempsensor | Temperature sensor (0, 1, 2, 3, 4) | 0 |  |

## Exemple de configuration pour evcc.yaml

```yaml
chargers:
    - name: my_heating
      type: template
      template: askoheat
      
      # Modbus TCP
      modbus: tcpip
      id: 1
      host:  # Hostname
      port: 502 # Port
      tempsensor: 0 # Temperature sensor, [0, 1, 2, 3, 4] (optional)
```