# Fronius Symo GEN24 Plus

Source: https://docs.evcc.io/fr/meters/fronius-symo-gen24-plus

To use active charge control, the Energy Cost Assistant (ECA) must not be activated in Fronius Solar.web. (Fronius Solar.web -> Settings -> Operating Mode -> Self-Consumption)
Meter address of primary or secondary meters: on the web interface of the inverter, only the address of the first meter (e.g., 200) can be set. Additional meters receive an ascending number (e.g., 201).

Fonctionnalités prises en charge: battery-control, curtail

## Paramètres

| Nom | Description | Par défaut / exemple | |
| --- | --- | --- | --- |
| modbus | Modbus Type (tcpip) |  |  |
| capacity | Battery capacity | 50 kWh |  |
| minsoc | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | 0 % |  |
| maxsoc | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | 100 % |  |
| maxchargepower | Maximum charge power For forced charging of the battery. |  W | avancé |
| maxdischargepower | Maximum discharge power Maximum discharge power of the storage. |  W | avancé |
| maxchargerate | Maximum charge rate For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. | 100 % | avancé |

## Exemple de configuration pour evcc.yaml

```yaml
meters:
    - name: my_grid
      type: template
      template: fronius-gen24
      usage: grid
      
      # Modbus TCP
      modbus: tcpip
      id: 200
      host:  # Hostname
      port: 502 # Port
```

```yaml
meters:
    - name: my_pv
      type: template
      template: fronius-gen24
      usage: pv
      
      # Modbus TCP
      modbus: tcpip
      id: 200
      host:  # Hostname
      port: 502 # Port
```

```yaml
meters:
    - name: my_battery
      type: template
      template: fronius-gen24
      usage: battery
      
      # Modbus TCP
      modbus: tcpip
      id: 200
      host:  # Hostname
      port: 502 # Port
      capacity: 50 # Battery capacity (kWh), optional
      minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
      maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
      maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
      maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
      maxchargerate: 100 # Maximum charge rate (%), For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. (optional)
```