# GoodWe HCA Wallbox (Gen2)

Fonte: https://docs.evcc.io/it/chargers/goodwe-hca-wallbox-gen2

Enable Modbus TCP in the SolarGo app via "Communication → Wallbox".
Default device ID is 247 (0xF7).
The wallbox only accepts 2 concurrent Modbus TCP sessions (1× SEMS cloud, 1× client). If the cloud is active, evcc competes for the second slot.
Note: Implementation is derived from the Home Assistant integration (gen2-modbus branch) and is not vendor-verified.

Funzionalità supportate: mA, rfid, 1p3p, meter

Token sponsor richiesto: questo dispositivo è disponibile per gli sponsor del progetto, vedi https://docs.evcc.io/it/sponsorship.

## Parametri

| Nome | Descrizione | Predefinito / esempio | |
| --- | --- | --- | --- |
| modbus | Modbus Type (tcpip) |  |  |

## Esempio di configurazione per evcc.yaml

```yaml
chargers:
    - name: my_charger
      type: template
      template: goodwe-wallbox
      
      # Modbus TCP
      modbus: tcpip
      id: 247
      host:  # Hostname
      port: 502 # Port
```