# E.G.O. Smart Heater

Bron: https://docs.evcc.io/nl/heating/e-g-o-smart-heater

The Smart Heater must be connected to the local network. Messages must be repeated at least every 60 seconds, otherwise the heater will turn off for safety reasons.

**Important:** In the loadpoint configuration, set `mincurrent: 0.2` and `maxcurrent: 16`, as well as `phases: 1` for single-phase operation.

Sponsortoken vereist: dit apparaat is beschikbaar voor sponsors van het project, zie https://docs.evcc.io/nl/sponsorship.

## Parameters

| Naam | Omschrijving | Standaard / voorbeeld | |
| --- | --- | --- | --- |
| modbus | Modbus Type (tcpip) |  |  |

## Configuratievoorbeeld voor evcc.yaml

```yaml
chargers:
    - name: my_heating
      type: template
      template: ego-smartheater
      
      # Modbus TCP
      modbus: tcpip
      id: 247
      host:  # Hostname
      port: 502 # Port
```