Skip to content
EN | DE

NRGkick Gen2

Supported features

  • mA regulation: Finer charging current regulation (mA instead of A) for better solar surplus use.
  • 1P/3P: Automatic phase switching. Useful for solar surplus charging.
  • Built-in meter: Support for an integrated meter.
  • Dimmable: Power consumption can be reduced (e.g. § 14a EnWG). See External Limit.

Parameters

NameDescriptionValueLevel
idModbus ID
Default: 1
intrequired
hostIP address or hostname
Example: 192.0.2.2
required
portPort
Default: 502
intrequired
phases1p3pPhase switching

Extended feature "Phase Switching" must be activated in the NRGKick app.

advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

chargers:
- name: my_charger
type: template
template: nrggen2
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
phases1p3p: # Phase switching, Extended feature "Phase Switching" must be activated in the NRGKick app. (optional)