SMA EV Charger Business
The 'Modbus TCP Server' must be enabled. The setting 'Register Address Set' must NOT be set to 'Phoenix' or 'TQ-DM100'. Use the third selection labeled 'Ebee', 'Bender', 'MENNEKES' etc. Set 'Allow UID Disclose' to On.
Firmware 5.33 or higher is required for phase switching (if supported by the model). The 'SEMP interface' must be enabled, the 'SEMP Charging Mode' must be set to 'Surplus Charging'. Set 'Software function to use phase switching' to SEMP.
For charging stations with two charging points (e.g. AMEDIO, Twincharge), each charging point must be configured separately. Set charging point 1 to Port 502 and charging point 2 to Port 503.
Supported features
- RFID: Integrated RFID card reader for vehicle identification.
- Dimmable: Power consumption can be reduced (e.g. § 14a EnWG). See External Limit.
Parameters
| Name | Description | Value | Level |
|---|---|---|---|
id | Modbus ID | int | required |
host | IP address or hostname | required | |
port | Port | int | required |
Configuration example for evcc.yaml
If you don't want to configure via the UI, you can alternatively use this YAML block.
chargers: - name: my_charger type: template template: bender-cc
# Modbus TCP modbus: tcpip id: 255 host: # Hostname port: 502 # Port