The Modbus TCP server must be enabled at the display under "Settings / Network" and the Modbus login code must be disabled (value 1) since evcc does not perform the login sequence. The PV status source must be set to "EMS" and the PV data source to the power setpoint at the display. Requires MIRA controller software V1.1.3 or later.

Supported features

  • Built-in meter: Support for an integrated meter.
  • Dimmable: Power consumption can be reduced (e.g. §14a EnWG). See External Control.

Parameters

NameDescriptionValueLevel
hostIP address or hostname
Example: 192.0.2.2
optional
tempsourceTemperature sourceoptional
wpmidHeat pump module slave id

Modbus slave id of the heat pump module (WPM 1 = 111 … WPM 8 = 118)

Default: 111
advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

chargers:
- name: my_heating
type: template
template: ovum-mira
host: 192.0.2.2 # IP address or hostname
tempsource: # Temperature source, [warmwater, buffer] (optional)
wpmid: 111 # Heat pump module slave id, Modbus slave id of the heat pump module (WPM 1 = 111 … WPM 8 = 118) (optional)