Atmoce MG100 M-gateway

Support for Atmoce MG100 (included with MC100 and MC100-T). Requires installer to enable Modbus TCP in configuration or through Atmozen app; available in firmware 01.01.00.18.10 or later. 'Grid Recharging' and 'Export Power' must be enabled in the Atmozen app to allow battery (dis)charging to/from grid.

Supported features

  • Battery control: External control of home battery charging and discharging via evcc.
  • Curtailable: Inverter production can be reduced (e.g. § 9 EEG). See External Limit.
  • Dimmable: Power consumption can be reduced (e.g. § 14a EnWG). See External Limit.

Usage areas

  • Grid meter
  • Solar production
  • Battery

Parameters

NameDescriptionValueLevel
idModbus ID
Default: 1
intrequired
hostIP address or hostname
Example: 192.0.2.2
required
portPort
Default: 502
intrequired
capacity [kWh]Battery capacity
Example: 50
optional
maxacpower [W]Maximum AC power of the hybrid inverter
Default: 0
Example: 5000
advanced
minsoc [%]Minimum charge

Lower limit when discharging the battery in normal operation

Default: 10
Example: 25
advanced
maxsoc [%]Maximum charge

Upper limit when charging the battery from the grid

Default: 100
Example: 95
advanced
maxchargepower [W]Maximum charge power

For forced charging of the battery.

advanced
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

advanced
firmwareFirmware version

Firmware 01.01.00.28.15 and higher allows for correct hold/holdcharge functionality, dimming and curtailing. Older versions only support hold function without (dis)charge.

Default: <01.01.00.28.15
advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

meters:
- name: my_grid
type: template
template: atmoce
usage: grid
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
firmware: <01.01.00.28.15 # Firmware version, Firmware 01.01.00.28.15 and higher allows for correct hold/holdcharge functionality, dimming and curtailing. Older versions only support hold function without (dis)charge. [<01.01.00.28.15, >=01.01.00.28.15] (optional)
meters:
- name: my_pv
type: template
template: atmoce
usage: pv
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
firmware: <01.01.00.28.15 # Firmware version, Firmware 01.01.00.28.15 and higher allows for correct hold/holdcharge functionality, dimming and curtailing. Older versions only support hold function without (dis)charge. [<01.01.00.28.15, >=01.01.00.28.15] (optional)
meters:
- name: my_battery
type: template
template: atmoce
usage: battery
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 10 # Minimum charge (%), Lower limit when discharging the battery in normal operation (optional)
maxsoc: 100 # Maximum charge (%), Upper limit when charging the battery from the grid (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
firmware: <01.01.00.28.15 # Firmware version, Firmware 01.01.00.28.15 and higher allows for correct hold/holdcharge functionality, dimming and curtailing. Older versions only support hold function without (dis)charge. [<01.01.00.28.15, >=01.01.00.28.15] (optional)