Fronius Symo GEN24 Plus

To use active charge control, the Energy Cost Assistant (ECA) must not be activated in Fronius Solar.web. (Fronius Solar.web -> Settings -> Operating Mode -> Self-Consumption) Meter address of primary or secondary meters: on the web interface of the inverter, only the address of the first meter (e.g., 200) can be set. Additional meters receive an ascending number (e.g., 201).

Supported features

  • Battery control: External control of home battery charging and discharging via evcc.
  • Curtailable: Inverter production can be reduced (e.g. § 9 EEG). See External Limit.

Usage areas

  • Grid meter
  • Solar production
  • Battery

Parameters

NameDescriptionValueLevel
idModbus ID
Default: 1
intrequired
hostIP address or hostname
Example: 192.0.2.2
required
portPort
Default: 502
intrequired
capacity [kWh]Battery capacity
Example: 50
optional
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Default: 0
Example: 25
optional
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Default: 100
Example: 95
optional
maxchargepower [W]Maximum charge power

For forced charging of the battery.

advanced
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

advanced
maxchargerate [%]Maximum charge rate

For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter.

Default: 100
advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

meters:
- name: my_grid
type: template
template: fronius-gen24
usage: grid
# Modbus TCP
modbus: tcpip
id: 200
host: # Hostname
port: 502 # Port
meters:
- name: my_pv
type: template
template: fronius-gen24
usage: pv
# Modbus TCP
modbus: tcpip
id: 200
host: # Hostname
port: 502 # Port
meters:
- name: my_battery
type: template
template: fronius-gen24
usage: battery
# Modbus TCP
modbus: tcpip
id: 200
host: # Hostname
port: 502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
maxchargerate: 100 # Maximum charge rate (%), For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. (optional)