Skip to content
EN | DE

Indevolt PowerFlex 3000 Hybrid

Local direct access to Indevolt devices (e.g. Solidflex series) via HTTP API on port 8080.

The device's IP address can be obtained from the Indevolt app, the router, or via UDP broadcast (port 10000). Assigning a static IP in the router is recommended.

Battery power sign convention and availability of grid import/export readings (registers 2101/2108) depend on installation (CT clamp) and should be verified.

See docs.indevolt.com.

Usage areas

  • Grid meter
  • Solar production
  • Battery

Parameters

NameDescriptionValueLevel
hostIP address or hostname
Example: 192.0.2.2
optional
capacity [kWh]Battery capacity
Example: 50
optional
minsoc [%]Minimum charge

Lower limit when discharging the battery in normal operation

Example: 25
optional
maxsoc [%]Maximum charge

Upper limit when charging the battery from the grid

Example: 95
optional
userUsername

e.g. email address, user id, etc.

advanced
passwordPassword

Service account password

advanced
cacheCache

Time interval for data refresh

Default: 5s
Example: 5m
advanced
maxchargepower [W]Maximum charge power

For forced charging of the battery.

advanced
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

meters:
- name: my_grid
type: template
template: indevolt-hybrid
usage: grid
host: 192.0.2.2 # IP address or hostname
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
cache: 5s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: indevolt-hybrid
usage: pv
host: 192.0.2.2 # IP address or hostname
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
cache: 5s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: indevolt-hybrid
usage: battery
host: 192.0.2.2 # IP address or hostname
capacity: 50 # Battery capacity (kWh), optional
minsoc: 25 # Minimum charge (%), Lower limit when discharging the battery in normal operation (optional)
maxsoc: 95 # Maximum charge (%), Upper limit when charging the battery from the grid (optional)
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
cache: 5s # Cache, Time interval for data refresh (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)