Skip to content
EN | DE

Zendure Solarflow 800 Pro

For active battery control, the local API must be enabled via the Zendure App (add HEMS and then exit to apply). The device serial number can be found in the Zendure App in the device settings.

Supported features

  • Battery control: External control of home battery charging and discharging via evcc.

Usage areas

  • Solar production
  • Battery

Parameters

NameDescriptionValueLevel
hostIP address or hostname
Example: 192.0.2.2
optional
serialSerial

Required only for active battery control. Device serial number (can be found in the Zendure App)

Example: WOB1NHMAMXXXXX3
optional
capacity [kWh]Battery capacity
Default: 1.92
Example: 50
optional
minsoc [%]Minimum charge

Lower limit when discharging the battery in normal operation

Example: 25
optional
maxsoc [%]Maximum charge

Upper limit when charging the battery from the grid

Example: 95
optional
maxacpower [W]Maximum AC power of the hybrid inverter
Default: 800
Example: 5000
advanced
maxchargepower [W]Maximum charge power

For forced charging of the battery.

Default: 1000
advanced
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

advanced
cacheCache

Time interval for data refresh

Default: 1s
Example: 5m
advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

meters:
- name: my_pv
type: template
template: zendure-solarflow-pro
usage: pv
host: 192.0.2.2 # IP address or hostname
maxacpower: 800 # Maximum AC power of the hybrid inverter (W), optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: zendure-solarflow-pro
usage: battery
host: 192.0.2.2 # IP address or hostname
serial: WOB1NHMAMXXXXX3 # Serial, Required only for active battery control. Device serial number (can be found in the Zendure App) (optional)
capacity: 1.92 # Battery capacity (kWh), optional
minsoc: 25 # Minimum charge (%), Lower limit when discharging the battery in normal operation (optional)
maxsoc: 95 # Maximum charge (%), Upper limit when charging the battery from the grid (optional)
maxchargepower: 1000 # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
cache: 1s # Cache, Time interval for data refresh (optional)