Amperfied Wallbox Energy Control

This page shows the nightly version. Switch to the release version.

Please read the wiring and configuration manual carefully. All boxes must be configured for external control in follower mode (DIP S5/4 OFF). Each box needs an individual Modbus ID (DIP S4). Ensure correct RS485 cabling including bus termination (DIP S6/2).

Supported features

  • mA regulation: Finer charging current regulation (mA instead of A) for better solar surplus use.
  • Built-in meter: Support for an integrated meter.
  • Dimmable: Power consumption can be reduced (e.g. §14a EnWG). See External Control.

Parameters

Modbus
NameDescriptionValueLevel
idModbus ID
Default: 1
intrequired
deviceDevice name

USB-RS485 adapter

Example: /dev/ttyUSB0
required
baudrateBaudrate
Default: 9600
required
comsetComSet

Communication parameter for the adapter

Default: 8N1
required
hostIP address or hostname
Example: 192.0.2.2
required
portPort
Default: 502
intrequired
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

chargers:
- name: my_charger
type: template
template: heidelberg
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8E1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: # Hostname
port: 502 # Port