Skip to content
smart charging

SEMP compatible

This page shows the nightly version. Switch to the release version.

SEMP (Smart Energy Management Protocol) compatible wallbox or device that can be controlled directly via HTTP/XML API. Configure the SEMP base URL (http://<charger-host>:8000/semp) and the device ID of the wallbox. IMPORTANT: The wallbox must NOT be registered directly as a consumer in the Sunny Home Manager / Sunny Portal at the same time!

Supported features

  • mA regulation: Finer charging current regulation (mA instead of A) for better solar surplus use.
  • 1P/3P: Automatic phase switching. Useful for solar surplus charging.
  • Built-in meter: Support for an integrated meter.
  • Dimmable: Power consumption can be reduced (e.g. § 14a EnWG). See External Limit.

Parameters

NameDescriptionValueLevel
uriSEMP base URL

HTTP(S) address

Example: http://192.168.0.10:8080/semp
optional
deviceidDevice ID (auto-detected if empty)

Explicit specification of a specific Device ID is only required for SEMP gateways with multiple subordinate devices.

Example: F-12345678-ABCDEF123456-00
advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

chargers:
- name: my_charger
type: template
template: semp-charger
uri: http://192.168.0.10:8080/semp # SEMP base URL, HTTP(S) address
deviceid: F-12345678-ABCDEF123456-00 # Device ID (auto-detected if empty), Explicit specification of a specific Device ID is only required for SEMP gateways with multiple subordinate devices. (optional)