Victron EV Charging Station

This page shows the nightly version. Switch to the release version.

Enter the host of the charger (not the GX device) and ensure that the charger is in manual mode.

To enable 1P/3P phase switching a hardware modification is required: the 4P contactor must be replaced with 2×2P contactors. The first contactor switches L1+N, the second switches L2+L3 and is controlled by the second relay on the PCB. Register 5100 must be set to 1 to enable phase switching. More info

Supported features

  • 1P/3P: Automatic phase switching. Useful for solar surplus charging.
  • Built-in meter: Support for an integrated meter.
  • Dimmable: Power consumption can be reduced (e.g. §14a EnWG). See External Control.

Parameters

NameDescriptionValueLevel
idModbus ID
Default: 1
intrequired
hostIP address or hostname
Example: 192.0.2.2
required
portPort
Default: 502
intrequired
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

chargers:
- name: my_charger
type: template
template: victron-evcs
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port