Awatt Electronic HEMS PRO (EEBus)

This page shows the nightly version. Switch to the release version.

Parameters

NameDescriptionValueLevel
skiSubject Key Identifier (SKI)

SKI of the FNN control box (shown in its web interface)

optional
ipIP address
Example: 192.0.2.2
optional
productionnominalmax [W]Installed generator power (Wp)

Rated generator/module power (Wp) of the installation.

optional
consumptionnominalmax [W]Max. consumption power (grid connection)

Contractual maximum power of the grid connection point reported to the control box. This is the connection capacity agreed with the grid operator, NOT the minimum consumption power (Pmin) of the control box. Default 24.15 kVA (3x35A).

advanced
failsafeconsumptionpower [W]Failsafe consumption limit (Pmin, LPC)

Failsafe minimum consumption power (Pmin) for controllable loads applied when the heartbeat from the control box is lost; it is overwritten by the control box once it transmits its own failsafe values. (Default 4.2 kW)

advanced
failsafeproductionpower [W]Failsafe production limit (LPP)

Remaining maximum feed-in power applied when the heartbeat from the control box is lost. Initial value; it is overwritten by the control box once it transmits its own failsafe values.

advanced
failsafedurationFailsafe minimum duration

Minimum time the failsafe limit stays active once entered. Initial value (default 2h); the control box overwrites it once it transmits its own value.

advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

hems:
type: template
template: hemspro-eebus
ski: # Subject Key Identifier (SKI), SKI of the FNN control box (shown in its web interface)
ip: 192.0.2.2 # IP address, optional
productionnominalmax: # Installed generator power (Wp) (W), Rated generator/module power (Wp) of the installation. (optional)
consumptionnominalmax: # Max. consumption power (grid connection) (W), Contractual maximum power of the grid connection point reported to the control box. This is the connection capacity agreed with the grid operator, NOT the minimum consumption power (Pmin) of the control box. Default 24.15 kVA (3x35A). (optional)
failsafeconsumptionpower: # Failsafe consumption limit (Pmin, LPC) (W), Failsafe minimum consumption power (Pmin) for controllable loads applied when the heartbeat from the control box is lost; it is overwritten by the control box once it transmits its own failsafe values. (Default 4.2 kW) (optional)
failsafeproductionpower: # Failsafe production limit (LPP) (W), Remaining maximum feed-in power applied when the heartbeat from the control box is lost. Initial value; it is overwritten by the control box once it transmits its own failsafe values. (optional)
failsafeduration: # Failsafe minimum duration, Minimum time the failsafe limit stays active once entered. Initial value (default 2h); the control box overwrites it once it transmits its own value. (optional)