Shelly Plus i4

This page shows the nightly version. Switch to the release version.

Connect the relay contacts of the control box to the inputs SW1 to SW4. All used inputs must be configured as input type "switch" in the Shelly app or web interface, not as "button".

Parameters

NameDescriptionValueLevel
hostIP address or hostname
Example: 192.0.2.2
optional
maxconsumptionpower [W]Guaranteed minimum power (Pmin)

Power limit applied to the root circuit while the limit is active.

optional
w4inputW4 input

Input number for the W4 signal (Dimmer for controllable loads), 1 to 4 (SW1 = 1)

Default: 1
optional
w3inputW3 input

Input number for the W3 signal (Zero export, 0%), 1 to 4 (SW1 = 1)

Default: 2
optional
passwordPassword

Only required if authentication is enabled on the device (user is always admin)

optional
productionnominalmax [Wp]Installed generator power

Rated generator/module power of the installation (reference value according to § 9 EEG).

optional
s1inputS1 input

Input number for the S1 signal (60% export power limit), 1 to 4 (SW1 = 1)

Example: 3
optional
s2inputS2 input

Input number for the S2 signal (30% export power limit), 1 to 4 (SW1 = 1)

Example: 4
optional
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

hems:
type: template
template: fnn-shelly-i4
host: 192.0.2.2 # IP address or hostname
maxconsumptionpower: # Guaranteed minimum power (Pmin) (W), Power limit applied to the root circuit while the limit is active.
w4input: 1 # W4 input, Input number for the W4 signal (Dimmer for controllable loads), 1 to 4 (SW1 = 1)
w3input: 2 # W3 input, Input number for the W3 signal (Zero export, 0%), 1 to 4 (SW1 = 1)
password: # Password, Only required if authentication is enabled on the device (user is always admin) (optional)
productionnominalmax: # Installed generator power (Wp), Rated generator/module power of the installation (reference value according to § 9 EEG). (optional)
s1input: 3 # S1 input, Input number for the S1 signal (60% export power limit), 1 to 4 (SW1 = 1) (optional)
s2input: 4 # S2 input, Input number for the S2 signal (30% export power limit), 1 to 4 (SW1 = 1) (optional)