Requires the Buderus MX400 or Bosch K40 RF gateway, firmware 15.00.01 or newer recommended.

Supported features

  • Built-in meter: Support for an integrated meter.
  • Dimmable: Power consumption can be reduced (e.g. § 14a EnWG). See External Limit.

Parameters

NameDescriptionValueLevel
skiSubject Key Identifier (SKI)

Usually found on the web interface of the wallbox

optional
ipIP address
Example: 192.0.2.2
optional
reboostReboost interval

Wait time after which a newly announced optional power consumption is scheduled again.

Default: 10m
advanced
disablepowerlimiterIgnore power limits

Do not use the device's announced optional power consumption as min/max power.

advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

chargers:
- name: my_heating
type: template
template: eebus-ohpcf-bosch
ski: # Subject Key Identifier (SKI), Usually found on the web interface of the wallbox
ip: 192.0.2.2 # IP address, optional
reboost: 10m # Reboost interval, Wait time after which a newly announced optional power consumption is scheduled again. (optional)
disablepowerlimiter: # Ignore power limits, Do not use the device's announced optional power consumption as min/max power. (optional)