Skip to content
EN | DE

LG Heat pump water heater (ThinQ)

This page shows the nightly version. There is no release version yet.

Controls LG heat pump water heaters (e.g. WH27S) via the LG ThinQ Connect cloud API. A personal access token (PAT) must be created at https://connect-pat.lgthinq.com with the permissions "view devices", "view device status" and "control devices". evcc sets the water heater target temperature: the normal temperature outside of boost, the boost temperature during boost.

Parameters

NameDescriptionValueLevel
tokenPersonal access token (PAT)optional
countryCountry code

Country code of the LG account (ISO 3166-1 alpha-2)

Default: DE
optional
deviceDevice ID

Required if multiple water heaters are present in the account

optional
normal [°C]Normal temperature

Target temperature outside of boost

Default: 50
optional
setpoint [°C]Boost temperature

Target temperature during boost, must exceed the normal temperature

Default: 60
optional
cacheCache

Time interval for data refresh

Default: 1m
Example: 5m
advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

chargers:
- name: my_heating
type: template
template: lg-thinq
token: # Personal access token (PAT)
country: DE # Country code, Country code of the LG account (ISO 3166-1 alpha-2) (optional)
device: # Device ID, Required if multiple water heaters are present in the account (optional)
normal: 50 # Normal temperature (°C), Target temperature outside of boost (optional)
setpoint: 60 # Boost temperature (°C), Target temperature during boost, must exceed the normal temperature (optional)
cache: 1m # Cache, Time interval for data refresh (optional)