NIBE Nibe S-Series (SG Ready)
Modbus connection to the NIBE S heat pump. Firmware version 4.13.12 or newer is required. Required settings in the control unit:
- In the indoor unit, Modbus must be enabled in menu 7.5.9
- To use power control, select Modbus ext. power limitation under AUX in menu 7.4. Set the minimum output of the immersion heater in the charging point settings.
- In menu 7.4, the options “SG-Ready A” and “SG-Ready B” must not be assigned.
- Enable "Activate SG-Ready via API" in menu 4.2.3.
Supported features
- Dimmable: Power consumption can be reduced (e.g. § 14a EnWG). See External Limit.
Parameters
| Name | Description | Value | Level |
|---|---|---|---|
id | Modbus ID | int | required |
host | IP address or hostname | required | |
port | Port | int | required |
tempsource | Temperature sensor | optional | |
powercontrol | power limitation | optional |
Configuration example for evcc.yaml
If you don't want to configure via the UI, you can alternatively use this YAML block.
chargers: - name: my_heating type: template template: nibe-s-series
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port tempsource: water_mid # Temperature sensor, [water_top, water_mid] powercontrol: true # power limitation