Skip to content
EN | DE

Stiebel Eltron WPM (SG Ready)

This page shows the nightly version. Switch to the release version.

SG Ready control via Modbus with the ISG only works in domestic hot water (DHW) mode and in automatic/programmed mode. In comfort mode, SG Ready commands are ignored.

Supported features

  • Built-in meter: Support for an integrated meter.
  • Dimmable: Power consumption can be reduced (e.g. § 14a EnWG). See External Limit.

Parameters

NameDescriptionValueLevel
idModbus ID
Default: 1
intrequired
hostIP address or hostname
Example: 192.0.2.2
required
portPort
Default: 502
intrequired
tempsourceTemperature sourceoptional
powerRead power consumption

Inverter power consumption. Only available on WPMsystem (WPM 4), not on WPM 3/3i.

advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

chargers:
- name: my_heating
type: template
template: stiebel-wpm
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
tempsource: # Temperature source, [warmwater, buffer] (optional)
power: # Read power consumption, Inverter power consumption. Only available on WPMsystem (WPM 4), not on WPM 3/3i. (optional)