Zewotherm EU-L Series
Energy management settings of the device:
- E-Meter communication type: "ModBus Client"
- E-Meter measuring point: "Energy-Input"
Supported features
- Built-in meter: Support for an integrated meter.
- Dimmable: Power consumption can be reduced (e.g. § 14a EnWG). See External Limit.
Parameters
| Name | Description | Value | Level |
|---|---|---|---|
id | Modbus ID | int | required |
host | IP address or hostname | required | |
port | Port | int | required |
tempsource | Temperature source | optional | |
firmware | Firmware version. Choose '>=1.1.3' for word-swap | optional | |
excess | deprecated, set for neg. e-excess to minus | advanced | |
watchdog | Watchdog | advanced |
Configuration example for evcc.yaml
If you don't want to configure via the UI, you can alternatively use this YAML block.
chargers: - name: my_heating type: template template: lambda-zewotherm
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port tempsource: # Temperature source, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional) firmware: <1.1.3 # Firmware version. Choose '>=1.1.3' for word-swap, [<1.1.3, >=1.1.3] (optional) excess: plus # deprecated, set for neg. e-excess to minus, [plus, minus] (optional) watchdog: 60s # Watchdog, optional