Fronius Primo GEN24 Plus
To use active charge control, the Energy Cost Assistant (ECA) must not be activated in Fronius Solar.web. (Fronius Solar.web -> Settings -> Operating Mode -> Self-Consumption) Meter address of primary or secondary meters: on the web interface of the inverter, only the address of the first meter (e.g., 200) can be set. Additional meters receive an ascending number (e.g., 201).
Supported features
- Battery control: External control of home battery charging and discharging via evcc.
- Curtailable: Inverter production can be reduced (e.g. § 9 EEG). See External Limit.
Usage areas
- Grid meter
- Solar production
- Battery
Parameters
| Name | Description | Value | Level |
|---|---|---|---|
id | Modbus ID | int | required |
host | IP address or hostname | required | |
port | Port | int | required |
capacity [kWh] | Battery capacity | optional | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | optional | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | optional | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | advanced | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | advanced | |
maxchargerate [%] | Maximum charge rate For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. | advanced |
Configuration example for evcc.yaml
If you don't want to configure via the UI, you can alternatively use this YAML block.
meters: - name: my_grid type: template template: fronius-gen24 usage: grid
# Modbus TCP modbus: tcpip id: 200 host: # Hostname port: 502 # Portmeters: - name: my_pv type: template template: fronius-gen24 usage: pv
# Modbus TCP modbus: tcpip id: 200 host: # Hostname port: 502 # Portmeters: - name: my_battery type: template template: fronius-gen24 usage: battery
# Modbus TCP modbus: tcpip id: 200 host: # Hostname port: 502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional) maxchargerate: 100 # Maximum charge rate (%), For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. (optional)