Skip to content
EN | DE

Fronius Verto Plus

This page shows the nightly version. Switch to the release version.

Supported features

  • Battery control: External control of home battery charging and discharging via evcc.

Usage areas

  • Grid meter
  • Solar production
  • Battery

Parameters

NameDescriptionValueLevel
hostIP address or hostname
Example: 192.0.2.2
optional
portPort
Default: 502
optional
capacity [kWh]Battery capacity
Example: 50
optional
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Example: 25
optional
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Example: 95
optional
idID

Meter address of primary or secondary meters. On the web interface of the inverter, only the address of the first meter (e.g., 200) can be set. Additional meters receive an ascending number (e.g., 201).

Default: 200
advanced
maxchargerate [%]Maximum charge rate

For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter.

Default: 100
advanced
maxchargepower [W]Maximum charge power

For forced charging of the battery.

advanced
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

meters:
- name: my_grid
type: template
template: fronius-vertoplus
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 502 # Port, optional
id: 200 # ID, Meter address of primary or secondary meters. On the web interface of the inverter, only the address of the first meter (e.g., 200) can be set. Additional meters receive an ascending number (e.g., 201). (optional)
meters:
- name: my_pv
type: template
template: fronius-vertoplus
usage: pv
host: 192.0.2.2 # IP address or hostname
port: 502 # Port, optional
meters:
- name: my_battery
type: template
template: fronius-vertoplus
usage: battery
host: 192.0.2.2 # IP address or hostname
port: 502 # Port, optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 25 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 95 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargerate: 100 # Maximum charge rate (%), For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)