Skip to content
EN | DE

IoTaWatt Energy Monitor

This page shows the nightly version. Switch to the release version.

Requires an IoTaWatt device accessible on the local network. Find available series names on the IoTaWatt status page (http://<device-host>). For single-phase setups, configure only the main series (e.g. GridNet, Solar). For three-phase, configure one series per phase (e.g. Grid_A, Grid_B, Grid_C).

Usage areas

  • Grid meter
  • Solar production
  • Charger meter

Parameters

NameDescriptionValueLevel
hostIP address or hostname
Example: 192.0.2.2
optional
seriesL1 / single-phase series

IoTaWatt series name (Watts). Check the IoTaWatt status page for available series.

Example: GridNet
optional
seriesL2L2 series (three-phase)

Series name for phase L2. Leave empty for single-phase.

advanced
seriesL3L3 series (three-phase)

Series name for phase L3. Leave empty for single-phase.

advanced
cacheCache

Time interval for data refresh

Default: 2s
Example: 5m
advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

meters:
- name: my_grid
type: template
template: iotawatt
usage: grid
host: 192.0.2.2 # IP address or hostname
series: GridNet # L1 / single-phase series, IoTaWatt series name (Watts). Check the IoTaWatt status page for available series.
seriesL2: # L2 series (three-phase), Series name for phase L2. Leave empty for single-phase. (optional)
seriesL3: # L3 series (three-phase), Series name for phase L3. Leave empty for single-phase. (optional)
cache: 2s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: iotawatt
usage: pv
host: 192.0.2.2 # IP address or hostname
series: GridNet # L1 / single-phase series, IoTaWatt series name (Watts). Check the IoTaWatt status page for available series.
seriesL2: # L2 series (three-phase), Series name for phase L2. Leave empty for single-phase. (optional)
seriesL3: # L3 series (three-phase), Series name for phase L3. Leave empty for single-phase. (optional)
cache: 2s # Cache, Time interval for data refresh (optional)
meters:
- name: my_charger
type: template
template: iotawatt
usage: charge
host: 192.0.2.2 # IP address or hostname
series: GridNet # L1 / single-phase series, IoTaWatt series name (Watts). Check the IoTaWatt status page for available series.
seriesL2: # L2 series (three-phase), Series name for phase L2. Leave empty for single-phase. (optional)
seriesL3: # L3 series (three-phase), Series name for phase L3. Leave empty for single-phase. (optional)
cache: 2s # Cache, Time interval for data refresh (optional)