Marstek Venus E Gen 3.0
Supported features
- Battery control: External control of home battery charging and discharging via evcc.
Usage areas
- Battery
Parameters
| Name | Description | Value | Level |
|---|---|---|---|
id | Modbus ID | int | required |
device | Device name USB-RS485 adapter | required | |
baudrate | Baudrate | required | |
comset | ComSet Communication parameter for the adapter | required | |
host | IP address or hostname | required | |
port | Port | int | required |
generation | Generation Venus E, Venus E Gen 2.0 and Venus C are generation 2. Generation 3 uses different registers. | optional | |
capacity [kWh] | Battery capacity | optional | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | optional | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | optional | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | advanced | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | advanced | |
work_mode_normal | Work mode for Normal state 0=manual, 1=anti-feed, 2=trade mode. | advanced |
Configuration example for evcc.yaml
If you don't want to configure via the UI, you can alternatively use this YAML block.
meters: - name: my_battery type: template template: marstek-venus-e usage: battery
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 502 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port generation: # Generation, Venus E, Venus E Gen 2.0 and Venus C are generation 2. Generation 3 uses different registers. [2, 3] capacity: 5.12 # Battery capacity (kWh), optional minsoc: 11 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) maxchargepower: 2500 # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: 800 # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional) work_mode_normal: 1 # Work mode for Normal state, 0=manual, 1=anti-feed, 2=trade mode. (optional)