Each of the four three-phase measuring circuits (X1 to X4) is configured as a separate meter, e.g. grid on X1 and charger on X2.

Wiring mode and current direction are configured on the device.

Usage areas

  • Grid meter
  • Solar production
  • Charger meter
  • Smart consumer

Parameters

Modbus
NameDescriptionValueLevel
idModbus ID
Default: 1
intrequired
deviceDevice name

USB-RS485 adapter

Example: /dev/ttyUSB0
required
baudrateBaudrate
Default: 9600
required
comsetComSet

Communication parameter for the adapter

Default: 8N1
required
hostIP address or hostname
Example: 192.0.2.2
required
portPort
Default: 502
intrequired
channelMeasuring circuit

Measuring circuit X1 to X4

Default: 1
optional
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

meters:
- name: my_grid
type: template
template: matismart-mpm4000
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
channel: 1 # Measuring circuit, Measuring circuit X1 to X4 [1, 2, 3, 4]
meters:
- name: my_pv
type: template
template: matismart-mpm4000
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
channel: 1 # Measuring circuit, Measuring circuit X1 to X4 [1, 2, 3, 4]
meters:
- name: my_charger
type: template
template: matismart-mpm4000
usage: charge
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
channel: 1 # Measuring circuit, Measuring circuit X1 to X4 [1, 2, 3, 4]
meters:
- name: my_aux
type: template
template: matismart-mpm4000
usage: aux
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
channel: 1 # Measuring circuit, Measuring circuit X1 to X4 [1, 2, 3, 4]