Solplanet Hybrid inverter (Modbus TCP)

This page shows the nightly version. There is no release version yet.

Only for inverters with a dedicated Modbus TCP ethernet port (e.g. ASW-TH series, KACO Blueplanet Hybrid NH3, port eth 5&6), protocol AISWEI "MB001_ASW GEN-Modbus" V2.1.7. Older devices without that port need the solplanet-ai-dongle template instead. The grid meter import/export energy counters (46443/46445) are not exposed over Modbus TCP by this firmware. With two battery packs (BMS1 + BMS2) add one battery meter each, using battery number 1 and 2.

Supported features

  • Battery control: External control of home battery charging and discharging via evcc.
  • Curtailable: Inverter production can be reduced (e.g. § 9 EEG). See External Limit.

Usage areas

  • Grid meter
  • Solar production
  • Battery

Parameters

NameDescriptionValueLevel
idModbus ID
Default: 1
intrequired
hostIP address or hostname
Example: 192.0.2.2
required
portPort
Default: 502
intrequired
batteryBattery numberoptional
maxchargepower [W]Maximum charge power

For forced charging of the battery.

optional
capacity [kWh]Battery capacity
Example: 50
optional
minsoc [%]Minimum charge

Lower limit when discharging the battery in normal operation

Example: 25
optional
maxsoc [%]Maximum charge

Upper limit when charging the battery from the grid

Example: 95
optional
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

advanced
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

meters:
- name: my_grid
type: template
template: solplanet-modbus
usage: grid
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
meters:
- name: my_pv
type: template
template: solplanet-modbus
usage: pv
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
meters:
- name: my_battery
type: template
template: solplanet-modbus
usage: battery
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
battery: # Battery number, [1, 2]
maxchargepower: # Maximum charge power (W), For forced charging of the battery.
capacity: 50 # Battery capacity (kWh), optional
minsoc: 25 # Minimum charge (%), Lower limit when discharging the battery in normal operation (optional)
maxsoc: 95 # Maximum charge (%), Upper limit when charging the battery from the grid (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)