Solvis SolvisControl 2/3

Modbus TCP must be enabled at the SolvisControl under "Settings / Network". Control is done via the hot water target temperature. The controller does not support power reduction (dim).

Supported features

  • Built-in meter: Support for an integrated meter.

Parameters

NameDescriptionValueLevel
hostIP address or hostname
Example: 192.0.2.2
optional
tempsourceTemperature source
Default: warmwater
optional
portPort
Default: 502
optional
tempnormalTarget temperature normal mode
Default: 48
optional
tempboostTarget temperature boost
Default: 60
optional
Configuration example for evcc.yaml

If you don't want to configure via the UI, you can alternatively use this YAML block.

chargers:
- name: my_heating
type: template
template: solvis
host: 192.0.2.2 # IP address or hostname
tempsource: warmwater # Temperature source, [warmwater, buffer]
port: 502 # Port, optional
tempnormal: 48 # Target temperature normal mode, optional
tempboost: 60 # Target temperature boost, optional