Solvis SolvisControl 2/3
Modbus TCP must be enabled at the SolvisControl under "Settings / Network". Control is done via the hot water target temperature. The controller does not support power reduction (dim).
Supported features
- Built-in meter: Support for an integrated meter.
Parameters
| Name | Description | Value | Level |
|---|---|---|---|
id | Modbus ID | int | required |
host | IP address or hostname | required | |
port | Port | int | required |
tempsource | Temperature source | optional | |
tempnormal | Target temperature normal mode | optional | |
tempboost | Target temperature boost | optional |
Configuration example for evcc.yaml
If you don't want to configure via the UI, you can alternatively use this YAML block.
chargers: - name: my_heating type: template template: solvis
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port tempsource: warmwater # Temperature source, [warmwater, buffer] tempnormal: 48 # Target temperature normal mode, optional tempboost: 60 # Target temperature boost, optional