Bender CC612
The 'Modbus TCP Server' must be enabled. The setting 'Register Address Set' must NOT be set to 'Phoenix' or 'TQ-DM100'. Use the third selection labeled 'Ebee', 'Bender', 'MENNEKES' etc. Set 'Allow UID Disclose' to On.
Firmware 5.33 or higher is required for phase switching (if supported by the model). The 'SEMP interface' must be enabled, the 'SEMP Charging Mode' must be set to 'Surplus Charging'. Set 'Software function to use phase switching' to SEMP.
For charging stations with two charging points (e.g. AMEDIO, Twincharge), each charging point must be configured separately. Set charging point 1 to Port 502 and charging point 2 to Port 503.
Podporované funkce
- RFID: Integrovaná čtečka RFID karet pro identifikaci vozidla.
- Regulovatelný odběr: Odebíraný výkon lze snížit (např. § 14a EnWG). Viz Externí limit.
Parametry
| Název | Popis | Hodnota | Úroveň |
|---|---|---|---|
id | Modbus ID | int | povinné |
host | IP adresa nebo název hostitele | povinné | |
port | Port | int | povinné |
Příklad konfigurace pro evcc.yaml
Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.
chargers: - name: my_charger type: template template: bender-cc
# Modbus TCP modbus: tcpip id: 255 host: # Hostname port: 502 # Port