Mennekes AMTRON 4Business 700 11 kW (OCPP)

Podporované funkce

Parametry

NázevPopisHodnotaÚroveň
stationidStation ID

Unique identifier of the charger. Automatically detected once the charger connects.

Příklad: EVB-P12354
volitelné
connectorConnector number

For multi-connector stations. Numbering starts at 1.

Výchozí: 1
pokročilé
chargingprofileCharging profile type

Use TxProfile only if the charger ignores TxDefaultProfile changes during an active transaction. Without a transaction, TxDefaultProfile is still used; an active transaction must report its ID. TxProfile expires with its transaction. The default profile is restored on the next control cycle. If evcc is offline then, the charger may charge without this limit until it reconnects.

Výchozí: TxDefaultProfile
pokročilé
remotestartStart remote transaction on vehicle connection

Only enable this option if there is no way to initiate transactions from the charger side! This is only the case if e.g. no RFID reader is available and charging processes would have to be released individually via app. Normally, the charger should always be configured at the device so that either an RFID card is used for activation or the charger is set to "Autostart", "Free Charging" or similar. First check the documentation and configuration possibilities of the charger, ask the manufacturer if necessary! (Uses OCPP RemoteStartTransaction)

pokročilé
idtagAuthentication token

This option is only required in exceptional cases if the charger requires a specific token for accepting external transactions. (Uses OCPP RemoteStartTransaction)

Příklad: evcc
pokročilé
connecttimeoutTimeout for registration

Timeout for the registration of the charging point

Výchozí: 5m
pokročilé
meterintervalTransmission interval for meter values

Time interval for transmission of meter values (MeterValueSampleInterval)

Výchozí: 10s
pokročilé
metervaluesMeter values for transmission

Manual specification of the meter values to be configured (MeterValuesSampledData)

Příklad: Energy.Active.Import.Register,Power.Active.Import,SoC,Current.Offered,Power.Offered,Current.Import,Voltage
pokročilé
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

chargers:
- name: my_charger
type: template
template: ocpp-mennekes-4you
stationid: EVB-P12354 # Station ID, Unique identifier of the charger. Automatically detected once the charger connects. (optional)
connector: 1 # Connector number, For multi-connector stations. Numbering starts at 1. (optional)
chargingprofile: TxDefaultProfile # Charging profile type, Use TxProfile only if the charger ignores TxDefaultProfile changes during an active transaction. Without a transaction, TxDefaultProfile is still used; an active transaction must report its ID. TxProfile expires with its transaction. The default profile is restored on the next control cycle. If evcc is offline then, the charger may charge without this limit until it reconnects. [TxDefaultProfile, TxProfile] (optional)
remotestart: # Start remote transaction on vehicle connection, Only enable this option if there is no way to initiate transactions from the charger side! This is only the case if e.g. no RFID reader is available and charging processes would have to be released individually via app. Normally, the charger should always be configured at the device so that either an RFID card is used for activation or the charger is set to "Autostart", "Free Charging" or similar. First check the documentation and configuration possibilities of the charger, ask the manufacturer if necessary! (Uses OCPP RemoteStartTransaction) (optional)
idtag: evcc # Authentication token, This option is only required in exceptional cases if the charger requires a specific token for accepting external transactions. (Uses OCPP RemoteStartTransaction) (optional)
connecttimeout: 5m # Timeout for registration, Timeout for the registration of the charging point (optional)
meterinterval: 10s # Transmission interval for meter values, Time interval for transmission of meter values (MeterValueSampleInterval) (optional)
metervalues: Energy.Active.Import.Register,Power.Active.Import,SoC,Current.Offered,Power.Offered,Current.Import,Voltage # Meter values for transmission, Manual specification of the meter values to be configured (MeterValuesSampledData) (optional)