Parametry

NázevPopisHodnotaÚroveň
skiSubject Key Identifier (SKI)

SKI of the FNN control box (shown in its web interface)

volitelné
ipIP address
Příklad: 192.0.2.2
volitelné
productionnominalmax [Wp]Installed generator power

Rated generator/module power of the installation (reference value according to § 9 EEG).

volitelné
consumptionnominalmax [W]Max. consumption power (grid connection)

Contractual maximum power of the grid connection point reported to the control box. This is the connection capacity agreed with the grid operator, NOT the minimum consumption power (Pmin) of the control box.

pokročilé
failsafeconsumptionpower [W]Failsafe consumption limit (Pmin, LPC)

Failsafe minimum consumption power (Pmin) for controllable loads applied when the heartbeat from the control box is lost; it is overwritten by the control box once it transmits its own failsafe values.

pokročilé
failsafeproductionpower [W]Failsafe production limit (LPP)

Remaining maximum feed-in power applied when the heartbeat from the control box is lost. Initial value; it is overwritten by the control box once it transmits its own failsafe values.

pokročilé
failsafedurationFailsafe minimum duration

Minimum time the failsafe limit stays active once entered. Initial value (default 2h); the control box overwrites it once it transmits its own value.

pokročilé
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

hems:
type: template
template: hemspro-eebus
ski: # Subject Key Identifier (SKI), SKI of the FNN control box (shown in its web interface)
ip: 192.0.2.2 # IP address, optional
productionnominalmax: # Installed generator power (Wp), Rated generator/module power of the installation (reference value according to § 9 EEG). (optional)
consumptionnominalmax: # Max. consumption power (grid connection) (W), Contractual maximum power of the grid connection point reported to the control box. This is the connection capacity agreed with the grid operator, NOT the minimum consumption power (Pmin) of the control box. (optional)
failsafeconsumptionpower: # Failsafe consumption limit (Pmin, LPC) (W), Failsafe minimum consumption power (Pmin) for controllable loads applied when the heartbeat from the control box is lost; it is overwritten by the control box once it transmits its own failsafe values. (optional)
failsafeproductionpower: # Failsafe production limit (LPP) (W), Remaining maximum feed-in power applied when the heartbeat from the control box is lost. Initial value; it is overwritten by the control box once it transmits its own failsafe values. (optional)
failsafeduration: # Failsafe minimum duration, Minimum time the failsafe limit stays active once entered. Initial value (default 2h); the control box overwrites it once it transmits its own value. (optional)