Přeskočit na obsah
chytré nabíjení

LG Heat pump water heater (ThinQ)

Controls LG heat pump water heaters (e.g. WH27S) via the LG ThinQ Connect cloud API. A personal access token (PAT) must be created at https://connect-pat.lgthinq.com with the permissions "view devices", "view device status" and "control devices". evcc sets the water heater target temperature: the normal temperature outside of boost, the boost temperature during boost.

Parametry

NázevPopisHodnotaÚroveň
tokenPersonal access token (PAT)volitelné
countryCountry code

Country code of the LG account (ISO 3166-1 alpha-2)

Výchozí: DE
volitelné
deviceDevice ID

Required if multiple water heaters are present in the account

volitelné
normal [°C]Normal temperature

Target temperature outside of boost

Výchozí: 50
volitelné
setpoint [°C]Boost temperature

Target temperature during boost, must exceed the normal temperature

Výchozí: 60
volitelné
cacheCache

Time interval for data refresh

Výchozí: 1m
Příklad: 5m
pokročilé
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

chargers:
- name: my_heating
type: template
template: lg-thinq
token: # Personal access token (PAT)
country: DE # Country code, Country code of the LG account (ISO 3166-1 alpha-2) (optional)
device: # Device ID, Required if multiple water heaters are present in the account (optional)
normal: 50 # Normal temperature (°C), Target temperature outside of boost (optional)
setpoint: 60 # Boost temperature (°C), Target temperature during boost, must exceed the normal temperature (optional)
cache: 1m # Cache, Time interval for data refresh (optional)