For demonstration purposes. Battery with a fixed set of values.

Oblasti využití

  • Baterie

Parametry

NázevPopisHodnotaÚroveň
power [W]Powervolitelné
soc [%]Chargevolitelné
controllableControllable

Supports active battery control

pokročilé
capacity [kWh]Battery capacity
Příklad: 50
pokročilé
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Výchozí: 0
Příklad: 25
pokročilé
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Výchozí: 100
Příklad: 95
pokročilé
maxchargepower [W]Maximum charge power

For forced charging of the battery.

pokročilé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

pokročilé
energy [kWh]Meter readingpokročilé
currentL1 [A]L1 currentpokročilé
currentL2 [A]L2 currentpokročilé
currentL3 [A]L3 currentpokročilé
maxacpower [W]Maximum AC power of the hybrid inverter
Výchozí: 0
Příklad: 5000
pokročilé
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

meters:
- name: my_battery
type: template
template: demo-battery
usage: battery
power: # Power (W), optional
soc: # Charge (%), optional
controllable: # Controllable, Supports active battery control (optional)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional