Přeskočit na obsah
chytré nabíjení

E3/DC

The communication is done locally. evcc must be in the same network as the E3/DC system.

Note: Active battery control will override Smart-Power/Operating Range settings.

Podporované funkce

  • Řízení baterie: Externí řízení nabíjení a vybíjení domácí baterie pomocí evcc.

Oblasti využití

  • Měřič sítě
  • Solární výroba
  • Baterie

Parametry

NázevPopisHodnotaÚroveň
hostIP address or hostname
Příklad: 192.0.2.2
volitelné
userUsername

Identical with Web Portal or E3/DC App.

volitelné
passwordPassword

Identical with Web Portal or E3/DC App.

volitelné
keyRSCP password

Must be set on the screen of your E3/DC system at 'Personalize' > 'User Profile'.

volitelné
portPort
Výchozí: 5033
volitelné
capacity [kWh]Battery capacity
Příklad: 50
volitelné
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Výchozí: 0
Příklad: 25
volitelné
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Výchozí: 100
Příklad: 95
volitelné
maxacpower [W]Maximum AC power of the hybrid inverter
Výchozí: 0
Příklad: 5000
pokročilé
externalpowerInclude external power

Includes all connected external sources into the PV calculation (default).

Výchozí: true
pokročilé
dischargelimitDischarge limit in W

Limits discharge power in 'Hold' battery mode

pokročilé
maxchargepower [W]Maximum charge power

For forced charging of the battery.

pokročilé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

pokročilé
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

meters:
- name: my_grid
type: template
template: e3dc-rscp
usage: grid
host: 192.0.2.2 # IP address or hostname
user: # Username, Identical with Web Portal or E3/DC App.
password: # Password, Identical with Web Portal or E3/DC App.
key: # RSCP password, Must be set on the screen of your E3/DC system at 'Personalize' > 'User Profile'.
port: 5033 # Port, optional
meters:
- name: my_pv
type: template
template: e3dc-rscp
usage: pv
host: 192.0.2.2 # IP address or hostname
user: # Username, Identical with Web Portal or E3/DC App.
password: # Password, Identical with Web Portal or E3/DC App.
key: # RSCP password, Must be set on the screen of your E3/DC system at 'Personalize' > 'User Profile'.
port: 5033 # Port, optional
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
externalpower: true # Include external power, Includes all connected external sources into the PV calculation (default). (optional)
meters:
- name: my_battery
type: template
template: e3dc-rscp
usage: battery
host: 192.0.2.2 # IP address or hostname
user: # Username, Identical with Web Portal or E3/DC App.
password: # Password, Identical with Web Portal or E3/DC App.
key: # RSCP password, Must be set on the screen of your E3/DC system at 'Personalize' > 'User Profile'.
port: 5033 # Port, optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
dischargelimit: # Discharge limit in W, Limits discharge power in 'Hold' battery mode (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)